Hand Magnet Yokes
Series HANSA of HELLING yoke magnets are convincing for their light, handy and efficient yokes. These yokes are convenient to use due to their small handle with roughened surface. They enable long, fatigue-free operation.
Series HANSA is available as following types:
Voltage |
UM 8 |
UM 9 |
UM 10 |
UM 15 |
|
230 V AC | main power supply | X | X | X | X |
42 V AC | main power supply | X | X | X | X |
6 V DC | battery power supply | - | X | X | - |
UM 8, UM 9 and UM 10 mainly differ by
- medium distance of poles
- side length
- lifting force
- weight
Basically, UM 15 is equipped with legs of three links, so that the distance between the poles can be adjusted from 90 to 245 mm.
Hand yokes of the series HANSA 230 and HANSA 42 fulfill the requirements of the following technical regulations
- | EN ISO 9934-3 | Non-destructive testing - Magnetic particle testing - Part 3: Equipment | |
- | ASTM E709-95 | Standard Guide for Magnetic Particle Examination | |
- | ASME Code Section V | Nondestructive Examination |
The requirement of the technical regulations concerning a lifting force of minimum 44 N (4.5 kg) and a tangential field force of minimum 20 A/cm is fulfilled.
Yokes of series HANSA DC include control of accumulator.
They comply with the requirements of
- | EN ISO 9934-3 | Non-destructive testing - Magnetic particle testing - Part 3: Equipment | |
- | ASTM E709-95 | Standard Guide for Magnetic Particle Examination | |
- | ASTM E1444 | Standard Practice for Magnetic Particle Testing |
The lifting force is greater than 265 N (27 kg). Thus, the respective requirement of ASTM E1444
(minimum 225 N / 22.5 kg) is fulfilled.
Scope of delivery
Hand yoke magnet with case
OPTIONAL
- with two links which are pivoting by 45° inwards and outwards
- with two links which are pivoting by 76° inwards and outwards
- screw-on
- with pin
- Test report

Mobile safety transformer according to VDE 0570 and EN 61558
Technical Data | ||
Input voltage |
230 V |




Technical Data |
|
Pole distance Pole cross section External dimension Tangential field strength Lifting force Voltage Operating current Power-on time Weight Cable length Protection class |
170 mm 25 x 25 mm 265 x 163 x 49 mm 30 A/cm 130 N 230 V 2 A 50 % 2.9 kg 5 m IP 65 |




Technical Data |
|
Pole distance Pole cross section External dimension Tangential field strength Lifting force Voltage Operating current Power-on time Weight Cable length Protection class |
170 mm 25 x 25 mm 265 x 163 x 49 mm 30 A/cm >130 N 42 V 9 A 50 % 2.9 kg 5 m IP 65 |
Necessary accessory:
Art. no. 131.009.050 | Safety transformer | 230/42 V |




Technical Data |
|
Pole distance Pole cross section External dimension Tangential field strength Lifting force Voltage Operating current Power-on time Weight Cable length Protection class |
170 mm 25 x 25 mm 250 x 135 x 49 mm 30 A/cm >130 N 230 V 2 A 50 % 2.9 kg 5 m IP 65 |




Technical Data |
|
Pole distance Pole cross section External dimension Tangential field strength Lifting force Voltage Operating current Power-on time Weight Cable length Protection class |
170 mm 25 x 25 mm 250 x 135 x 49 mm 32 A/cm >130 N 42 V 8.5 A 50 % 2.9 kg 5 m IP 65 |
Necessary accessory:
Art. no. 131.009.050 |
Safety transformer |
230/42 V |




Technical Data |
|
Pole distance |
170 mm 25 x 25 mm 250 x 135 x 49 mm >225 N 6 V 1 A 4 h 2.9 kg IP 65 |



Technical Data |
|
Pole distance Pole cross section External dimension Tangential field strength Lifting force Voltage Operating current Power-on time Weight Cable length Protection class |
135 mm 25 x 25 mm 210 x 110 x 49 mm 30 A/cm > 90 N 230 V 0.8 A 50 % 2.2 kg 5 m IP 65 |




Technical Data |
|
Pole distance Pole cross section External dimension Tangential field strength Lifting force Voltage Operating current Power-on time Weight Cable length Protection class |
135 mm 25 x 25 mm 210 x 110 x 49 mm 30 A/cm >90 N 42 V 4.4 A 50 % 2.2 kg 5 m IP 65 |
Necessary Accessory:
Art. no. 131.009.056 |
Safety transformer |
230/42V 630VA |




Technical Data |
|
Pole distance |
170 mm 25 x 25 mm 210 x 110 x 49 mm >225 N 6 V 1 A 4 h 2.2 kg IP 65 |



Technical Data |
|
Pole distance Pole cross section External dimension Tangential field strength Lifting force Voltage Operating current Power-on time Weight Cable length Protection class |
95 - 245 mm 25 x 25 mm 255 x 173 x 45 mm 23 A/cm > 45 N 230 V 3 A 50 % 3.2 kg 5 m IP 65 |




Technical Data |
|
Pole distance Pole cross section External dimension Tangential field strength Lifting force Voltage Operating current Power-on time Weight Cable length Protection class |
95 - 245 mm 25 x 25 mm 255 x 173 x 45 mm 20 A/cm >45 N 42 V 9 A 50 % 3.2 kg 5 m IP 65 |
Necessary accessory:
Art. no. 131.009.050 |
Safety transformer |
230/42 V |