Image Quality Indicator
Detectability of details of a radiographic film essentially depends on the image quality of the radiographic film.
The different image quality indicators (IQI) and their application for determination of the image quality number are described in standards such as EN ISO 19232 "Non-destructive testing. Image quality of radiographs. "
IQIs are delivered together with a declaration of conformity (e.g. acc. to ISO/IEC-Guide 22)

- Seven parallel wires of different diameters
- Material: aluminium, titanium, steel or copper
- Length of the wires: 10, 25 or 50 mm
- Embedded in a transparent plastic covering (including indication of standard, number of thickest wire, material and length by white or non-ferrous metal symbols)
- Marked by batch number
Type Diameter of wire (mm)
W13 W10 W6 W1 |
0.050 0.100 0.25 0.80 |
0.063 0.125 0.32 1.00 |
0.080 0.160 0.40 1.25 |
0.100 0.200 0.50 1.60 |
0.125 0.250 0.63 2.00 |
0.160 0.320 0.80 2.50 |
0.200 0.400 1.00 3.20 |
Scope of delivery
- IQ
- Box
- Declaration of conformity




































Determination of image unsharpness
- 13 pairs of wires of decreasing wire diameter (1D - 13D)
- 1D - 3D consist of tungsten, the others are made of platinum
- Evaluation of X-ray films with magnifying glass (max. magnification 4x)
- Image unsharpness "U" is determined by the wire pair whose two wires can be recognised just disconnected
- Application in connection with IQI wire penetrameter or step/hole IQI is recommended
Element no. | Image unsharpness "U" | Wire Diameter = wire distance |
13D | 0.10 | 0.050 mm |
12D | 0.13 | 0.063 mm |
11D | 0.16 | 0.080 mm |
10D | 0.20 | 0.100 mm |
9D | 0.26 | 0.130 mm |
8D | 0.32 | 0.160 mm |
7D | 0.40 | 0.200 mm |
6D | 0.50 | 0.250 mm |
5D | 0.64 | 0.320 mm |
4D | 0.80 | 0.400 mm |
3D | 1.00 | 0.500 mm |
2D | 1.26 | 0.630 mm |
1D | 1.60 | 0.800 mm |
Scope of delivery
- IQI
- Box
- Conformity declaration













- Six parallel wires of different diameters
- Material: aluminium, titanium, steel, copper or inconel
- Imbedded in a transparent plastic cover (indication of wire material, range of thickness, thickest wire diameter through lead signs)
- Labeled by batch number
Type | Material | Diameter of wire |
Typ 1 A01 | FE | 0.08 - 0.25 mm |
Typ 1 B03 | FE | 0.25 - 0.81 mm |
Typ 1 C10 | FE | 0.81 - 2.50 mm |
Typ 1 D32 | FE | 2.50 - 8.00 mm |
Typ 02 A01 | AL | 0.08 - 0.25 mm |
Typ 02 B03 | AL | 0.25 - 0.81 mm |
Typ 02 C10 | AL | 0.81 - 2.50 mm |
Typ 4 A01 | CU | 0.08 - 0.25 mm |
Typ 4 B03 | CU | 0.25 - 0.81 mm |
Typ 4 C10 | CU | 0.81 - 2.50 mm |
Typ 01 A01 | TI | 0.08 - 0.25 mm |
Typ 01 B03 | TI | 0.25 - 0.81 mm |
Scope of delivery
- IQI
- Conformity declaration
- Box












- Rectangular steel badge; of equal thickness as test specimen
- Penetrameter number (lead number on the badge)
- 3 bore holes (beginning with badge 12: 4-fold, single and twice material thickness )
Scope of delivery
Penetrameter supplied with batch number, conformity declaration and box
Art.-No. Type Min. wall thickness