X-ray Film Viewing

RB-2 LED
- Evaluation of film densities up to D ≤ 4.1
- Fixed basic brightness to prevent glare
- Stepless brightness adjustment, after actuating the foot switch
- Automatic changeover to basic brightness after releasing foot switch
- Main cable and foot switch connected by plug
- 2 additional covering masks
Technical Data Illuminated area Pinhole aperture Luminance |
|
Film density Operation voltage Power input Dimensions Weight Control of light intensity |
Up to D = 4.1 acc. to EN 25580 100-240 V 50-60 Hz 170 W 412 x 210 x 173 mm Approx. 6.3 kg Manually or with foot switch |
RB-2 LED | Film Viewer
246.000.100 Film Viewer RB-2 LED

RB-3 LED
- Evaluation of film densities up to D ≤ 4,1
- Foot switch operated adjustment basic brightness to prevent glare
- Stepless brightness adaption
- Main cable and foot switch connected by plug
- Additional covering masks for 6 cm width films
Technical Data Illuminated area Luminance |
|
Film density Operation voltage Power input Dimensions Weight |
Up to D = 4.1 |
RB-3 LED | Film Viewer
246.000.110 Film viewer RB-3 LED
Product flyer
RB-2 Light Box
- Evaluation of film densities up to D ≤ 3.75
- Light intensity of main light controllable manually or by connected foot switch
- A preset background brightness remains after switching off the main light by foot operation. Thus, adaptation time is reduced.
Technical Data Illuminated area Pinhole aperture Additional aperture Luminance Film density Light sources Operation voltage Power input Dimensions Weight Control of light intensity |
200 x 85 mm ∅ 30 mm 200 x 50 mm (for 60 mm films) 60,000 cd/m² bis D = 3.75 1 x halogen, 1,000 W 230 V 50 Hz 1 kVA 400 x 260 x 225 mm 8 kg Manually or by foot switch |
RB-2 | Film Viewer
241.002.000 RB-2 film viewer
241.002.050 RB-2 test report


RB 3 Lght Box
- Evaluation of film densities up to D ≤ 3.65
- Light intensity of main light controllable manually or by steadily connected foot switch
- A preset background brightness remains after switching off the main light by foot operation. Thus, the adaptation time is reduced.
Technical Data Illuminated area Pinhole aperture Additional aperture Luminance Film density Light sources Operation voltage Power input Dimensions Weight Control of light intensity |
440 x 85 mm ∅ 30 mm 440 x 50 mm (for 60 mm films) 45,000 cd/m² bis D = 3.65 11 x halogen, 24 v at 150 W 230 V 50 Hz 1.4 kVA 660 x 260 x 225 mm 12 kg Manually or by foot switch |
RB-3 | Film Viewer
241.003.000 RB-3 film viewer
241.002.050 RB-3 test report